Linkam Scientific Instruments.
							
Leaders in heating, cooling and freezing microscope stages.

Examina Dynamic temperature control system

Temperature programmers Heating and Freezing Microscope Stages Cooling Systems
Complete Systems
Heating and Cooling Stages
Software
Image Capture
Warm Microscope Stages
Optical Accessories
Microscope Stage Clamps
Custom Projects
What's New
Contact us
About Us
Site Map
Examina Dynamic Back to General Applications

Features and Benefits

The THMS600 is one of the most widely used heating and freezing stages on the market. Over 800 stages have been sold around the world to date, it is used in many applications where high heating/freezing rates and 0.1°C accuracy and stability are needed.

The sample is loaded on a 0.17mm cover slip on a highly polished silver heating element to ensure excellent heat transfer and extremely sensitive temperature measurement. A platinum resistor sensor, accurate to 0.01°C provides far more accurate and stable temperature signal that can be achieved with a thermocouple.

The temperature is programmed by the standalone TMS94 temperature progammer. Sophisticated temperature profiles of up to 32 ramps can be set up with ranges of heating rates from 0.1C/min to 130C/min.

The TMS94 can be used as a standalone programmer or connected via RS232 to PC enabling use of further features within the Linksys software. TMS94 firmware can be updated via email using the RS232 connection.

Samples can be quickly characterized by heating to within a few degrees of the temperature of interest at a rate of 130C/min then slowed down to a few degrees a minute to closely examine sample changes utilising a variety of microscopy techniques. The entire experiment can be saved as an online plot or exported to a spreadsheet application.

Download Product Data for Entire Examina Range

examina dynamix system

More information about working distances can be found on the Optical Accessories page

  • Temperature range -196° to 600°C (cooling option required)
  • Up to 130°C/min heating
  • 32 ramp temperature profile programming
  • No PC required
  • Temperature stability <0.1°C
  • 16 mm X,Y sample manipulation
  • Sample area 22 mm diameter
  • Gas tight chamber for atmospheric control
  • Clamps directly to the microscope substage for stability
  • 100ohm platinum resistor sensor. 1/10th Din Class A to 0.1°C
  • Light aperture - 2.4mm Ø
  • Silver heating block for high thermal conductivity
  • Direct injection of the coolant into the silver block
  • Single ultra thin lid window - 0.17mm
  • Objective lens working distance - 0.1mm to 4.5mm
  • Condenser lens minimum working distance 12.5mm
  • Range of condenser extension lenses available
  • Can be used with all microscope techniques
  • Water cooled stage body for high temperature work (>300°C)
  • Suitable for Confocal, Laser Raman and X-Ray
  • Sample side loading without removing the stage lid
  • Stage body size - 137 x 92 x 22 mm

Examina Dynamix system includes:

THMS600 stage

TMS94 computer interface controller

All necessary cables

Cooling option required to extend range to -196°C

THM-LNP94/2 automated liquid nitrogen cooling pump
THM-LNP94/1 manual control liquid nitrogen cooling pump

 

[Complete Systems] [System Products] [Software] [Image Capture] [Warm Microscope Stages] [Optical Accessories] [Custom Projects] [What's New] [Contact Us] [About Us] [Site Map]

Linkam Scientific Instruments Ltd · (+44)(0) 1737 363 476. FAX (+44)(0) 1737 363 480

© Copyright, 2007 Linkam Scientific Instruments, All Rights Reserved.

Unauthorized use of any content contained herein is strictly prohibited.